Clean Room Validation A

Our company accumulates years of testing experience, providing customers with multiple aspects of testing services based on SOP for clean room tests.

All our test instruments pass calibration by original manufacturers, performing periodical calibration followed with instrument calibration certificate to ensure conforming to individual accuracy.

Therefore, our company would provide a detailed test report after completion of tests, filing for customers and reserved for reference of long-term following-up and communication.

Test Items and Instruments Used
Test Item Instrument/Brand/Model
Cleanliness Test PARTICLE COUNTER / METONE 3400 SERIES
Leak Test PARTICLE COUNTER / RION-KM-20 / MET ONE-A2100B
Temperature/Humidity Test Humidity / Temperature Meter/VAISALA-HMI 31
Clean Room Validation B Velocity/RION-AM 09S
Illuminance Test Lumenmeter/TES-1330
Room Pressure Test Pressure gage/TESTO-DMS 0638.1545
Noise Test Sound-meter/TES-1350A
Features for Particle Measuring Test Instrument
  • World-patent optic design:Passive Laser Cavity Design- Outer diameter He-Ne-Laser, Stable light source strength-Filter Purge Air, preventing optic lens
    contamination-2 years warranty for optic system wit easy
    replacement and maintenance.
  • Seven paints for optional use:suitable for monitoring clean
    rooms of CLASS 1 to 100,000.
  • Range for tested particulate diameter:0.1~0.5μm
  • Maximum allowed concentration:750.000/ft3
  • Tested flow:1CFM conformed to FS209E regulations standard
FED-STD-209 Measuring Point Area Standard
Sample Location and Number (Unidirectional Airflow)
  • Sample locations must be evenly distributed in the sampling area
  • Sample locations must conform to (a)or(b)

(a)SI unit : A/2.32 (m2)
  Englih unit : A/25(ft2)
  A refers to area of clean room, for class 1 ~ 100.

 

(b)SI unit : A*64(10m)0,5 (m2) M : if class 1000=M4.5>M=4.5
  English unit : A/(Nc)0.5 (ft2) Nc : if class 1000 Nc=1000
  A refers to area of clean room
  M and Nc are respectively class of clean room, for class 1000~100000. Result stands for
  number of measuring locations.
  Ps : There shall be at least two locations for each area.

Number of Samples Required
  • Each location shall be measured at least once.
  • There shall be at least five samples for each area (Area; Room).
Test Items and Instruments Used

Numbers of Locations & Samples Requires Per Cleanroom Area

L=Locations=Less of (Area÷25 or Area ÷ √ class; but no less than 2 per Area)
S=Samples=5minimum Per Area; but no less than 1 per locaion
Class Class 1 10 100 1000 10000 100000
Area
(m2)
Area
(ft2)
L S L S L S L S L S L S
2.4 25 2 5 2 5 2 5 2 5 2 5 2 5
9.3 100 4 5 4 5 4 5 4 5 2 5 2 5
20.9 225 9 9 9 9 9 9 8 8 3 5 2 5
37.2 400 16 16 16 16 16 16 13 13 4 5 2 5
83.7 900 36 36 36 36 36 36 29 29 9 9 3 5
232.3 2500 100 100 100 100 100 100 79 79 25 25 8 8
929.0 10000 400 400 400 400 400 400 316 316 100 100 32 32
 The Area are examples and to be used only for reference